![]() Returns: If the protocol stack has been disabled it returns eMBErrorCode::MB_ENOERR. This function disables processing of Modbus frames. Examples: LINUX/demo.c, MCF5235TCP/demo.c, STR71XTCP/demo.c, WIN32/demo.cpp, and WIN32TCP/demo.cpp. If the protocol stack is not in the disabled state it returns eMBErrorCode::MB_EILLSTATE. Returns: If the resources where released it return eMBErrorCode::MB_ENOERR. A port which wants to get an callback must define the macro MB_PORT_HAS_CLOSE to 1. Note: Note all ports implement this function. It must only be called when the protocol stack is disabled. ![]() This function disables the Modbus protocol stack and release all hardware resources. Release resources used by the protocol stack. Read register values and pass to protocol stack. See also: eMBRegHoldingCB( ), eMBRegCoilsCB( ), eMBRegDiscreteCB( ) and eMBRegInputCB( ). Writing means that the application registers should be updated and reading means that the modbus protocol stack needs to know the current register values. This value is passed to the callback functions which support either reading or writing register values. Please note that this values are actually passed to the porting layer and therefore not all parity modes might be available. The parity which should be applied to the characters sent over the serial link. Parity used for characters in serial mode. ASCII is slower and more reliable on slower links (E.g. RTU is faster but has more hardware requirements and requires a network with a low jitter. Modbus serial supports two transmission modes. Modbus serial transmission modes (RTU/ASCII). eMBPoll( ) ĮMBInit ( eMBMode eMode, UCHAR ucSlaveAddress, UCHAR ucPort, ULONG ulBaudRate, eMBParity eParity)ĮMBSetSlaveID (UCHAR ucSlaveID, BOOL xIsRunning, UCHAR const *pucAdditional, USHORT usAdditionalLen)ĮMBRegisterCB (UCHAR ucFunctionCode, pxMBFunctionHandler pxHandler)Įxamples: MCF5235TCP/demo.c, STR71XTCP/demo.c, and WIN32TCP/demo.cpp.Įrrorcodes used by all function in the protocol stack.Įxamples: AT91SAM7X_ROWLEY/demo.c, AVR/demo.c, LINUX/demo.c, MCF5235/demo.c, MCF5235TCP/demo.c, MSP430/demo.c, STR71X/simple2.c, STR71XTCP/demo.c, WIN32/demo.cpp, and WIN32TCP/demo.cpp. Call the main polling loop of the Modbus protocol stack. Initialize protocol stack in RTU mode for a slave with address 10 = 0x0A eMBInit( MB_RTU, 0x0A, 38400, MB_PAR_EVEN ) Test Center (Compose your own test strings)Ģ8 Display formats such as float, double etc.Įasy control of RS-485 converters with RTS toggleĭevelopment 圆4, protocol 圆4, monitor 圆4, data 圆4 OLE Automation for easy interface to Excel using Macro language VBA MODBUS POLL Technical Facts and Features: edit data in Excel and then transmit the data to your slave device! Try the Excel example.xlsm installed with the program. To interpret and show the Modbus data according to your specific requirements. ![]() OLE Automation for interfacing with Excel. If you are a slave developer you can compose and send your own test strings in the "test center" and check the result from the slave in hex numbers. Multiple data formats such as float, double and long with word order swapping are available.Įxception errors are shown on the status line. ![]() Or you can change multiple registers/coils. If you want to change a single register, simply double click the value. You can read and write registers and coils from any window. For each window you simply specify the Modbus slave ID, function, address, size and poll rate. With the multiple document interface you can monitor several Modbus slaves and/or data areas at the same time. Modbus Poll is a Modbus master simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. Top Software Keywords Show more Show less
0 Comments
Leave a Reply. |